Measure positive and negative DC voltage with this five-digit bidirectional panel meter. It uses three-wire common-ground connections, a separate 4–30V supply and automatic decimal-point shifting across the documented±33V measurement range.
33.000 V
5-digit high-precision positive and negative bidirectional voltmeter
This product uses independent AD chip sampling, has strong performance and high accuracy, can measure positive and negative bidirectional voltage, supports automatic decimal point shifting, three-wire common ground wiring, can be powered independently or share a power supply, making the wiring more convenient.
Product Name: Five-digit 33 V Positive and Negative Bidirectional Measurement Voltmeter
Working Voltage: DC4~30 V, 5 V power supply recommended
Working Current: ≈15 mA
Measurement Range: -33.00~0.0000~33.000 V
Resolution: 0.0001 V or 0.001 V (automatic decimal point displacement)
Error Range: ±0.264 V
Product Size: 47.57×19.45×28.58 mm
Installation Opening: 45×26 mm
Standard lead wire
XH-2.54-3P Red, Black and Yellow Wires (Thin Wire Total Length: 155 mm)
Thin red wire: Working power supply positive terminal, do not connect to a power supply above 30 V
Thin black wire: Working power supply negative terminal, connected to the thick black wire at the construction site, no connection needed when sharing a power supply
Thin yellow wire: Voltage test wire, connect to the positive terminal of the test circuit power supply

Voltage display fine-tuning
This is a display fine-tuning, not a major calibration. It adjusts the displayed voltage and cannot adjust the actual voltage!
See that circular variable resistor pointed to by the arrow? Find a flat-head screwdriver and gently turn it!
Why poke so hard! Do you think you are doing a nucleic acid test? Be gentle, don't break it!!!
No-load display does not return to zero
When only the red and black wires are connected without the yellow wire, a non-zero reading indicates an idle display that does not return to zero. A forced zeroing operation is required. If this single operation is unsuccessful, it must be repeated multiple times. If strong interference exists in the usage environment, forced zeroing may fail, resulting in an inability to return to zero; in such cases, the displayed value can only be calculated as system error.
The forced zeroing operation is as follows:
① Disconnect the instrument power supply
② Find the forced zero endpoint on the back of the meter.
③ Short-circuit the forced zero end point with pointed tweezers or other conductive objects,
④ Connect a 4-30 V power supply to the red and black wires.
⑤ After the digital tube lights up, disconnect the short-circuit point
⑥ Operation complete.
Ratings & reviews
Reviews are temporarily unavailable. Please try again later.
Review submission is temporarily unavailable. Only customers who purchased this product can submit a review when the service is available.
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Questions are temporarily unavailable. Please try again later.
Question submission is temporarily unavailable. Please try again later.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.