Skip to content
Cart0 items in cart
Menu

Brand: AurumPCB

3String12V18650Lithium battery protection board 11.1V 12.6V With balance25A Overcurrent, overcharge, and over-discharge protection

Sale price: $1.60Regular price: $1.76(-9%)

30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.

Color: 3String12V25A

Product details

Description

3S 12.6 V 25 A Lithium Battery Protection Board with Balance

This three-series lithium protection board combines charge balancing with a documented 25 A continuous discharge rating. The specification table includes cell protection thresholds, balancing current, and recovery conditions for overcurrent and short-circuit events.

Product details

Specifications
Continuous Discharge Current: 25 A
Instantaneous Discharge Current: 75 A
Charging Voltage: Lithium Battery Charger 12.6 V, Switching Power Supply 13-16 V
Charging Current: 25 (max) A
Overcharge Detection Voltage: 4.28±0.05 V per cell
Overcharge Protection Delay: 0.5S
Overcharge Release Voltage: 4.08±0.05 V per cell
Charge Balance Detection Voltage: 4.2±0.05 V
Charge Balance Release Voltage: 4.2±0.05 V
Charge Balance Current: 45 mA
Over-discharge Detection Voltage: 2.55±0.08 V
Product details 2
Over-discharge detection delay: 0.1S
Over-discharge release voltage: 2.9±0.1 V
Overcurrent detection voltage: 150 mV
Overcurrent detection delay: 10mS
Overcurrent protection current: 75±5 A
Overcurrent protection release condition: Disconnect load
Short-circuit protection condition: External load short circuit
Short-circuit detection delay: 250uS
Short-circuit protection release condition: Disconnect load
Main circuit conduction internal resistance: ≤20MΩ
Operating current: ≤30 uA
Sleep current (when over-discharged): ≤20 uA
Temperature range: -20 °C to 80 °C
Product details 3
Product Size: 56.6 × 50 × 1 mm
Product Weight: 10g
3S 12.6 V 25 A Lithium Battery Protection Board with Balance — wiring and connection diagram

Note: For better consistency balancing, try to use a 13 V switching power supply for charging (auto-stop current below 30 mA). Because the balancing current of the balancing IC is around 45 mA, and most 12.6 V lithium battery chargers on the market will auto-stop when the charging current detection is below 100 mA, resulting in no charge coming in before balancing, causing voltage imbalance between each battery group. Regarding the issue of voltage drop between the battery voltage and the output terminal voltage, the working principle of this type of protection board is negative electrode protection. When just assembled, some may experience a voltage drop of 0.1-0.3 V. After several cycles of charging and discharging, the voltage drop will decrease, which is a normal phenomenon. Try not to use a 12 V power supply for the charger. The full charge point of a 3-series lithium battery is 12.6 V. Charging with a 12 V power supply will result in incomplete charging, and the protection board will not protect either, so it will keep charging. Long-term use will affect battery life. Thank you for your understanding.

Product details 4
Fault Phenomenon Fault Inspection and Cause Handling Method and Warranty
Unable to discharge First connect a suitable charger for charging, then measure the voltage of the 3 cells separately. If the voltage of one cell is below approximately 2.7 V, the protection board will activate over-discharge protection. Pair each battery properly; do not mix good batteries with poor ones (if unresolved, contact after-sales service).
Unable to charge Measure the voltage of the 3 cells. If the voltage of one cell exceeds approximately 4.23 V, the protection board will activate overcharge protection. Pair each battery properly; do not mix good batteries with poor ones (if unresolved, contact after-sales service).
Product details 5
Charging/discharging failure Incorrect wiring of B- (0 V), B1 (3.7 V), B2 (7.4 V), and B+ (11.1 V) Rewire or replace with a new board (man-made fault, return allowed with customer-paid shipping)
Overcharge/over-discharge failure Incorrect wiring of B- (0 V), B1 (3.7 V), B2 (7.4 V), and B+ (11.1 V) Rewire or replace with a new board (man-made fault, return allowed with customer-paid shipping)
Discharge protection Check whether the load's startup current exceeds the overcurrent protection threshold of the protection board. Replace with a higher-current protection board (outside operating range, return allowed with customer-paid shipping)
Component cold solder joint One pin of the component is not connected to the PCB pad. Re-solder it yourself (if unresolved, contact after-sales service for return)
Component solder bridge Short circuit between two or more pins of the component. Remove the component and re-solder it (if unresolved, contact after-sales service for return)
Electrostatic discharge damage With no power applied, measure the G, D, and S terminals of the MOSFET; both forward and reverse resistance between any two pins are 0 Ω. Remove and replace the MOSFET yourself (if unresolved, contact after-sales service for return)
Note: The company operates with integrity and guarantees that every product has been tested with a professional protection board tester before shipment. Since combining protection boards with battery packs may occasionally result in damage from electrostatic discharge or current surges, occasional defective units during use are normal. Our battery pack department also uses protection boards daily to assemble battery packs, with a defect rate of approximately 0.5%. Therefore, the company accepts after-sales service for any unit within the warranty period, even if previously soldered or damaged by human error.
  1. Can my battery use this protection board of yours?

Answer: Whether you can use this protection board depends on two questions to consider: First, how many cells in series is your battery? You must buy a protection board with the corresponding number of series cells. Second, what material is your battery made of? We have protection boards for two types of parameters: lithium iron phosphate and polymer lithium batteries. If your battery is a single cell of lithium iron phosphate with a nominal voltage of 3.2 V, you need to select the Lithium Iron Phosphate 3.2 V category. If it is a polymer (ternary, cobalt acid, manganese acid lithium battery) single cell with a nominal voltage of 3.6 V (or 3.7 V), please select the Polymer 3.7 V category.

  1. How do I judge what material my battery is made of?

Answer: You can look at the nominal voltage of your battery. Lithium iron phosphate batteries are generally marked as 3.2 V, while other batteries are generally marked as 3.6 V or 3.7 V. You can also directly ask the seller what material the battery is made of. Many buyers say their battery is 18650 or 26650 pouch, etc., but that is the shape, not the material! We cannot determine your battery protection parameters based on this.

  1. How many Amps (A) should I choose for the protection board?

Answer: Choosing how many Amps (A) for the protection board depends on the power of your product or the current limit of the controller. For example, choose 10 A for under 100 W, 20 A for under 200 W, 25 A for under 300 W. For over 500 W, please contact us via Wangwang first. The protection board current cannot be less than the controller's current limit.

  1. My battery is 20AH, can I use this protection board?

Answer: The size of your battery capacity actually has no direct relationship with the current size of using this board. Large capacity does not mean large battery; it mainly depends on continuous current. That is to say, the greater your power, the greater the continuous current of the protection board you choose needs to be. It has no direct relationship with your battery capacity.

  1. How should the charger voltage be set?

Lithium batteries must be charged with a dedicated lithium battery charger. Do not use lead-acid battery chargers. Lead-acid charging may result in high voltage breaking down the MOS tube of the protection board, causing the protection board to fail to protect against overcharging.

Charger voltage setting: Use your battery pack series count * 4.2 V, this is the charging voltage for non-iron lithium batteries. The charging voltage for iron lithium batteries is battery series count * 3.60 V, this is the charging voltage for iron lithium batteries. The standard charging current is 0.2 times the capacity.

3S 12.6 V 25 A Lithium Battery Protection Board with Balance — circuit board and component detail
3S 12.6 V 25 A Lithium Battery Protection Board with Balance — circuit board and component detail
3S 12.6 V 25 A Lithium Battery Protection Board with Balance — installation on a battery pack
3S 12.6 V 25 A Lithium Battery Protection Board with Balance — rear view of the board

Shipping & support

  • Ships from China.

    We deliver to most countries worldwide. Shipping charges are shown at checkout.

  • Tracked delivery.

    Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.

  • Need express shipping?

    Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.

  • Technical help.

    Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.

  • If a product arrives defective:

    contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.

  • Bank transfer orders.

    Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.

Cart

0

Your cart is empty.

Looks like you haven't added anything to your cart yet.

Search