Image 1 of 4
Brand: AurumPCB
30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.
This battery management board range provides balancing and charge/discharge monitoring for three-series to five-series lithium packs. The documentation distinguishes common-port and separate-port configurations with different output-current ratings and chemistry-specific versions.
3/4/5 Series Lithium Battery Protection Board
Charge and Discharge Protection
Short Circuit Protection
Overcurrent Protection
Overtemperature Protection
Balancing Protection
Output current:
Common port 80 A
Separate port 100 A
When the battery reaches full charge, it will be protected.
When the battery discharges to a certain level, the battery will have discharge protection.
To prevent excessive current in the battery, overcurrent protection is applied to the battery.
To prevent short circuits in the battery, short-circuit protection is applied to the battery.
When the battery is nearly fully charged, the balancing circuit is activated to maintain balance.
This lithium battery protection board adopts a highly integrated smart lithium battery protection board all-in-one chip, with performance superior to protection boards composed of discrete chips. It can complete charge and discharge protection for 3/4/5 series polymer lithium batteries, ternary lithium batteries, lithium iron phosphate, lithium cobalt oxide, and lithium manganese oxide batteries, as well as overcurrent, short circuit, over-temperature protection, and balancing functions.
Universal for single and split ports
Universal for common and separate ports, highly applicable. Suitable for battery pack applications in various fields such as inverters, DC motors, power tools, and solar street lights.
Adopts 4 milliohm ultra-low internal resistance MOS transistors, low circuit internal resistance, high efficiency.
| Protection Item | Polymer/Ternary Lithium Manganese Lithium Battery Protection Parameters | Lithium Iron Phosphate Battery Protection Parameters | |
|---|---|---|---|
| Single Cell Overcharge Protection Voltage | 4.25 V ±0.025 V | 3.75 V ±0.025 V | |
| Single Cell Overcharge Release Voltage | 4.15 V ±0.05 V | 3.55 V ±0.05 V | |
| Overcharge Protection Delay | 1S ±200mS | 1S ±200mS | |
| Single Cell Over-discharge Protection Voltage | 2.7 V ±0.05 V | 2.0 V ±0.05 V | |
| Single Cell Over-discharge Release Voltage | 3.0 V ±0.1 V | 2.7 V ±0.1 V | |
| Over-discharge Protection Delay | 1S ±200mS | 1S ±200mS | |
| Discharge Overcurrent Protection | 120 A | 120 A | |
| Discharge Overcurrent Protection Delay | 100mS ±50mS | 100mS ±50mS | |
| Short Circuit Protection | Yes | Yes | |
| Short Circuit Protection Delay | 250uS ±50uS | 250uS ±50uS | |
| Short Circuit Protection Recovery Method | Disconnect load to restore output voltage | Disconnect load to restore output voltage | |
| Discharge Current | 80 A (For over 30 A, please pile solder on the tinned part of PCB or add copper wire to increase current capacity) | 80 A (For over 30 A, please pile solder on the tinned part of PCB or add copper wire to increase current capacity) | |
| Charging Current | 80 A (For over 30 A, please pile solder on the tinned part of PCB or add copper wire to increase current capacity) | 80 A (For over 30 A, please pile solder on the tinned part of PCB or add copper wire to increase current capacity) | |
| Balancing Function | Yes | Yes | |
| Balancing Activation Voltage | 4.18 V ±0.025 V | 3.5 V ±0.025 V | |
| Balancing Current | 55 mA | 55 mA | |
| Wire Break Protection | Yes | Yes | |
| Temperature Protection | Yes (Effective when external 10K ohm NTC resistor is connected) | Yes (Effective when external 10K ohm NTC resistor is connected) | |
| Low Temperature Charging Protection | -7 °C | -7 °C | |
| High Temperature Charging Protection | 50 °C | 55 °C | |
| High Temperature Discharge Protection | 70 °C | 75 °C | |
| Module Size | 62 × 62 × 8 mm | ||
In the same-port mode, it supports a discharge current of 80 A and a charging current of 80 A; in the separate-port mode, the discharge current is 100 A and the charging current is 100 A.






Common Questions
Question 1: How to choose the amperage of the protection board? Is it related to battery capacity?
Answer: The choice of amperage for the protection board depends on the magnitude of your load working current and has no direct relationship with battery capacity; a larger capacity indicates a longer usable time. For general loads, we can select one greater than 1.5-2 times the load working current. If too small, it is prone to false overcurrent protection; if too large, it will not provide protection. For loads with very high starting currents, such as high-power DC motors, power tools, inverters, and loads containing large-capacity electrolytic capacitors, the working current value should be appropriately increased.
Question 2: How to choose between a 3.7 V or a 3.2 V protection board?
Answer: Check whether the nominal voltage on the battery is 3.2 V or 3.7 V. For batteries without labels, ask the battery seller what the nominal voltage is, or what material the battery is made of. Generally, polymer lithium batteries are 3.7 V, and lithium iron phosphate batteries are 3.2 V.
Question 3: What are the conditions for connecting batteries in series or parallel?
Answer: When batteries are connected in series or parallel to form a battery pack for application, the battery capacity and internal resistance must be matched. Batteries of different capacities and types cannot be mixed, nor can new and old batteries be mixed, as this will affect the lifespan of the battery pack.
Question 4: Can protection boards for different series counts and different materials be used interchangeably?
Answer: The protection board should be selected according to the number of battery cells in series. Mixing them will cause abnormal operation of the protection board and fail to provide protection. Protection boards that can be used interchangeably for different series counts also need to have their parameters set according to the actual series count before use. Batteries of different materials have different protection parameters and cannot be used interchangeably.
Question 5: How to choose a charger? Can the charger be omitted if there is a protection board?
Answer: For charging lithium batteries, a dedicated charger or a DC-DC charging module should be selected. The charging voltage should be chosen based on the number of battery cells in series and the battery material. Do not omit the charger just because the protection board has an overcharge protection function, as this may lead to battery overcharging.
Ratings & reviews
No reviews yet. Purchased this product? Share your experience.
Checking review eligibility…
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Be the first to ask about this product.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.