


Image 1 of 4
Brand: AurumPCB
30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.
This digital panel meter measures circuit voltage and current, with separate fine adjustment for the displayed readings. Its measurement function does not regulate the connected supply; the wiring guide distinguishes operating power from measurement connections.
200 V 10 A
Introduction to parameters and usage tutorial for 4-digit DC voltage and current meter
This is a voltage, current, and power measurement instrument. It can only measure and display the voltage, current, and power of the circuit under test. The displayed values can be fine-tuned via an adjustable resistor. It does not have step-up/step-down voltage or current limiting/regulation functions, and it does not affect the actual voltage and current of the circuit under test.
When in use, do not operate at high voltages above 30 V, otherwise it will cause overvoltage damage to the product.
The 10 A range product comes with a built-in shunt resistor. Directly measuring current at the test terminals will result in a short circuit. As long as the instrument is connected in series with the load according to the wiring diagram, it can be used normally.

Working Voltage
The instrument working voltage is DC 4~30 V, recommended 5~12 V.
The thin red wire is the positive pole of the working power supply, and the thin black wire is the negative pole of the working power supply, sharing a common ground with the thick black wire;
When in use, the limit voltage connected to the thin red and black wires cannot exceed 30 V, 12 V power supply is recommended
DC4~30 V
Range
Voltage measurement range 0~200 V, display mode below 10 V is 0.00 V, voltage starts at 0.3 V, error range ±1 V, current measurement range 0~10 A, current starts at 0.03 A, error ±0.1 A
DC0.30 V~9.999~10.00~200.0 V (±1 V)
DC0.030 A~9.999 A (±0.1 A)
Shunt (Manganin Post)
On-board shunt resistor, no external shunt required. Connect directly according to the wiring diagram for use.
The shunt resistor is in parallel with the current test leads. An open-circuit test will trigger a short-circuit alarm. When in use, connect the thick red wire in series according to the wiring diagram to
Load negative terminal normal use
Standard wire
XH-2.54-3P Red Black Yellow Wires (Total length of thin wires: 155 mm)
Thin red wire: Positive terminal of working power supply, do not connect to a power supply above 30 V
Thin black wire: Negative terminal of working power supply, connected to the thick black wire ground, no need to connect when sharing power supply
Thin yellow wire: Voltage test wire, connect to positive terminal of test circuit power supply
VH-3.96-2P Red and Black Wires (Total Length of Thick Wire: 165 mm) Current Test Lead
Thick Red Wire: Positive terminal for current testing, connected in series with the negative end of the load; connect last and disconnect first when wiring is broken.
Thick Black Wire: Negative terminal for current testing, connected to the negative pole of the power supply; connect first and disconnect last when wiring is broken.
Voltage display fine-tuning
It is a display fine-tuning, not a major calibration; it adjusts the displayed voltage, not the actual voltage!
See that circular variable resistor labeled VR? Find a flathead screwdriver and gently twist it!
Why poke so hard! Do you think this is acid testing? Be gentle, don't break it!!!
Current Display Fine Adjustment
It is a display fine adjustment, not a major calibration; it adjusts the displayed current and cannot adjust the actual current!
See that circular adjustable resistor for IR? It looks just like the one for voltage fine adjustment. Poke it gently!
No-load current does not return to zero
The product has a built-in simulator. In the absence of interference, the no-load current automatically returns to zero. If the no-load current cannot return to zero, it indicates that there is interference in the environment, which can only be counted as system error.
Problem Description
Solution
Problem 1
Use a multimeter to test for a short circuit in the thick red and black wires.
Connect a shunt resistor in parallel. Under normal conditions, just wire it according to the wiring diagram and use it normally!
Problem 2
The digital tube does not light up when connected.
Disconnect the thick wires, connect the thin red and black wires to a 5-20 V DC power supply. If it lights up, it's a wiring problem; check the wiring against the wiring diagram. If it doesn't light up, then the meter is already broken. I don't know how it broke, I just know it's broken!
Problem 3
There is a current reading displayed when no load is connected.
This is non-zero return under no load. Look above for the solution.
Problem 4
When testing solar energy, it does not start initially and needs to be restarted once before it can be used.
The working voltage was not supplied enough at one time, causing it to stall. Independent power supply will work.
Ratings & reviews
Reviews are temporarily unavailable. Please try again later.
Review submission is temporarily unavailable. Only customers who purchased this product can submit a review when the service is available.
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Questions are temporarily unavailable. Please try again later.
Question submission is temporarily unavailable. Please try again later.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.







