


Image 1 of 4
Brand: AurumPCB
30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.
This battery protection board range covers multiple series counts for lithium battery assemblies. The documentation includes cell-tap connection order and chemistry-dependent protection thresholds; match the version and wiring to the specific pack.
Before connecting the protection board, do not insert the ribbon cable into the board first. Remember! Incorrectly connecting the ribbon cable will burn out the board!
After connecting the ribbon cable and battery in order, check that the adjacent voltages are correct before inserting the ribbon cable; then connect B- with a short thick wire, followed by C- (P-).
The protection board should be installed near the negative terminal of the battery. The wire connected to B- should be as short and thick as possible, with its length controlled within 10 cm. It is recommended to use 4 mm² wire for the 50 A version and 6 mm² wire for the 80 A version.
| Protection Item | Min | Typ | Max | Unit |
|---|---|---|---|---|
| Overcharge Voltage | 4.23 | 4.25 | 4.27 | V |
| Overcharge Recovery Voltage | 4.14 | 4.19 | 4.24 | V |
| Overcharge Voltage Protection Delay | 700 | 1000 | 1300 | mS |
| Over-discharge Voltage | 2.72 | 2.8 | 2.88 | V |
| Over-discharge Recovery Voltage | 2.9 | 3 | 3.1 | V |
| Over-discharge Voltage Protection Delay | 105 | 140 | 175 | mS |
| Over-discharge Protection Current | 54 | 60 | 66 | A |
| Separate Port Discharge Current (Continuous) | 26 | A | ||
| Common Port Discharge Current (Continuous) | 18 | A | ||
| Over-discharge Current Protection Delay | 18 | 24 | 30 | mS |
| Overcharge Protection Current | 32 | 40 | 48 | A |
| Charging Current (Continuous) | 18 | A | ||
| Overcharge Current Protection Delay | 12 | 16 | 20 | mS |
| Static Current | 25 | μA | ||
| Temperature Protection | With Temperature Control Interface | |||
| Wire Break Protection | None | |||
| Short Circuit Protection | None | |||
| Short Circuit Delay | None | |||
| Overcurrent Protection Recovery Method | Release by Disconnecting Load | |||
| Balancing Function | None | |||
| Balancing Current | None | |||
| Body Dimensions | 55.1 × 31.5 × 7.6 | |||
| Body Color | Green | |||
| Body Weight | 33.5 (including ribbon cable) | |||
| Standard Accessories | Circuit board, 14-pin ribbon cable | |||
| Standard Packaging | Anti-static bag | |||
| Wire Specification | 24AWG 14-pin ribbon cable | |||
| Wire Length | 40 | |||
| Operating Temperature | -20 °C ~ +65 °C | |||
| Storage Temperature | -40 °C ~ +85 °C | |||
| Protection item | Min | Typ | Max | Unit |
|---|---|---|---|---|
| Overcharge voltage | 3.725 | 3.75 | 3.775 | V |
| Overcharge recovery voltage | 3.55 | 3.6 | 3.65 | V |
| Overcharge voltage protection delay | 1000 | 1300 | 1600 | mS |
| Over-discharge voltage | 2.05 | 2.1 | 2.15 | V |
| Over-discharge recovery voltage | 2.25 | 2.3 | 2.35 | V |
| Over-discharge voltage protection delay | 115 | 145 | 175 | mS |
| Over-discharge protection current | 56 | 66 | 76 | A |
| Separate port discharge current (continuous) | 26 | A | ||
| Common port discharge current (continuous) | 18 | A | ||
| Over-discharge current protection delay | 9 | 12 | 15 | mS |
| Overcharge protection current | 110 | 130 | 150 | A |
| Charging current (continuous) | 18 | A | ||
| Overcharge current protection delay | 6 | 8 | 12 | mS |
| Static current | 25 | μA | ||
| Temperature protection | With temperature control interface | |||
| Wire breakage protection | None | |||
| Short circuit protection | None | |||
| Short circuit delay | None | μS | ||
| Overcurrent protection recovery method | Release by disconnecting load | |||
| Balancing function | None | |||
| Balancing current | None | mA | ||
| Body size | 55.1 × 31.5 × 7.6 | mm | ||
| Body color | Green | |||
| Body weight | 33.5 (including ribbon cable) | g | ||
| Standard accessories | Circuit board, 14-pin ribbon cable | |||
| Standard packaging | Anti-static bag | |||
| Wire specifications | 24AWG 14-pin ribbon cable | |||
| Wire length | 40 | cm | ||
| Operating temperature | -20 °C ~ +65 °C | °C | ||
| Storage temperature | -40 °C ~ +85 °C | °C |






Step 1: Connect the B- wire to the negative terminal of the lithium battery pack.
Step 2: Connect the ribbon cable (Ensure the ribbon cable is unplugged from the protection board. Start wiring from B-. Connect B- to the main negative terminal of the lithium battery pack. Connect the second wire of the ribbon cable, B1, to the positive terminal of the first cell string of the lithium battery pack. Connect the third wire, B2, to the positive terminal of the second cell string of the lithium battery pack. The subsequent...
Step 3: Insert the ribbon cable after checking that there are no errors.
Step 4: Connect the C- wire.
Step 5: Measure whether the total voltage of the lithium battery is equal to the voltage from C- to the positive terminal of the battery (the board works normally only if they are equal).


1: The B-, C-, and P- wires must be connected with thick wire, and ensure the pads are correctly soldered to the positive and negative terminals of the corresponding device.
2: Before installing the protection board, the batteries must be well-matched (the voltage difference between each cell should not exceed 0.05 V, the internal resistance difference should not be greater than 5mΩ, and the capacity difference should be less than 30 mAh). The protection board protects each battery string; it will activate if the voltage of any string is too high or too low. The better the consistency of the batteries, the longer the overall battery life will last, and the best working performance of the protection board can be achieved.
3: Single cells need to be first connected in parallel to form battery packs of the required quantity, and then these packs should be used in series.
4: When connecting battery packs in series, please ensure that the voltage of each pack is the same. If they are different, fully charge each pack individually before using them in series. During discharge testing, the pack whose voltage drops fastest is a poor-quality battery.
5: Do not mix good batteries with poor-quality ones for use. The closer the capacity and internal resistance of the battery packs are, the better.
6: Lithium battery protection boards are strictly prohibited from being used in series.
Answer: Whether you can use this protection board depends on two considerations: First, how many cells in series your battery has; you need to buy a protection board with the corresponding number of series cells. Second, what material is your battery made of? We have protection boards with parameters for Lithium Iron Phosphate and Polymer. If your battery is Lithium Iron Phosphate with a nominal voltage of 3.2 V per cell, you need to select the Lithium Iron Phosphate 3.2 V category. If it is Polymer (Ternary, Cobalt Acid, Manganese Acid Lithium Battery) with a nominal voltage of 3.6 V (or 3.7 V) per cell, please select the Polymer 3.7 V category.
Answer: You can check the nominal voltage of your battery. Lithium Iron Phosphate batteries are generally marked as 3.2 V, while other batteries are generally marked as 3.6 V or 3.7 V. You can also directly ask the seller of the battery cells what material they are. Many buyers say their battery is 18650 or 26650 pouch, etc., but that is the shape, not the material! We cannot determine your battery protection parameters based on that.
Answer: Choosing how many amps for the protection board depends on your load power. Our protection boards have common port output. The maximum current for 1-series output is 16 A, and the maximum current for 2-series output is 25 A.
Answer: The capacity of your battery actually has no direct relationship with the current rating of using this board. Large capacity does not mean large battery size; mainly look at the continuous current. That is to say, the larger your load, the larger the continuous current of the protection board you choose needs to be. It has no direct relationship with battery capacity.
Answer: Lithium batteries must be charged with a dedicated lithium battery charger. Do not use lead-acid battery chargers. Lead-acid charging may result in high voltage breaking down the MOS tube of the protection board, causing the protection board to fail to protect against overcharging. Charger voltage setting: Use your battery pack series count * 4.2 V, which is the charging voltage for non-Lithium Iron Phosphate batteries. The charging voltage for Lithium Iron Phosphate batteries is battery series count * 3.60 V. The standard charging current is 0.2 times the capacity.
Ratings & reviews
Reviews are temporarily unavailable. Please try again later.
Review submission is temporarily unavailable. Only customers who purchased this product can submit a review when the service is available.
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Questions are temporarily unavailable. Please try again later.
Question submission is temporarily unavailable. Please try again later.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.







