Image 1 of 4
Brand: AurumPCB
30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.
Battery capacity tester using an external discharge load and a micro-USB power connection. The specification lists a 1–15V discharge range, adjustable termination voltage and current measurement up to 3A, with resistor-selection guidance in the description.
Product Information
| Power Supply Voltage: | DC4.5-6 V (micro USB interface) |
|---|---|
| Operating Current: | Not exceeding 70 mA |
| Discharge Voltage: | 1.00 V-15.00 V |
| Resolution: | 0.01 V |
| Termination Voltage Range: | 0.5-11.0 V |
| Supported Through Current: | 3.000 A |
| Resolution: | 0.001 A |
| Voltage Measurement Error: | 1%+0.02 V |
| Current Measurement Error: | 1.5%+-0.008 A |
| Battery Capacity Range: | 9999 Ah (1 Ah=1000 mAh) |
| Circuit Board Size: | 50mmX37 mm |
| Finished Product Size: | 50mmX37mmX17 mm |
|---|---|
| Product Weight: | 26.9g |

Product Description
Method for estimating the matching resistor: According to Ohm's law, estimated resistance value = battery voltage divided by the expected discharge current. The selection of resistor power should be more than twice the result of battery voltage multiplied by the expected discharge current. It is important to note that the full charge voltage of the battery is relatively high; it must be ensured that the current does not exceed 3.0 A at full charge voltage! For example, if a 2 A current is needed to test a 12 V storage battery, the resistor needs to be 6 Ω with a power rating of 50 W. The full charge voltage of a new 12 V storage battery is approximately 13.5 V. At this time, the corresponding current is 13.5/6 = 2.25 A, which is less than 3 A, so it can be used. Additionally, if using a light bulb for testing, the current can only be taken as half (1.5 A) because the cold-state resistance of the light bulb is very low, and the startup surge current is very large. Choosing too large a value may directly burn out the circuit!!!!
Note: During the process of discharging with a resistor, the resistive load will heat up severely. Please pay attention to safety!
Battery capacity range: 9999 Ah (1 Ah=1000 mAh). The large value is switched by moving the decimal point. When it is below 10 Ah, it displays as X.XXX; when it reaches above 10 Ah, it displays as XX.XX, and so on.
Note: To improve voltage measurement accuracy, this circuit has been specially designed with a DC bias. When nothing is connected to the terminals, a very small voltage will be displayed, which does not affect actual measurements. If you short-circuit the input terminals (0 V), it will display 0. Those who want to understand the principle can refer to the superposition theorem in electrical engineering.
Usage method:
1. The battery under test should be fully charged.
2. Connect the positive terminal of the battery under test to the positive input, and the negative terminal to the negative input. Do not reverse the connections (reversing connections while loaded may damage the circuit)! Connect the load to the positive output and negative output, and supply working power to the tester via micro USB (do not use desktop or laptop USB for power supply). At this time, the battery voltage is displayed.
3. To directly start testing, simply press the "OK" button once. The tester can automatically set an appropriate termination voltage based on the battery's full charge voltage, and it will flash. Displays 3 times before starting the test. To manually set the termination voltage, simply
In the battery voltage display state, press the "+" or "-" button to modify. The termination voltage is displayed starting with P, followed by the voltage value, with a resolution of 0.1 V. After setting, press "OK" to start testing.
4. After the test starts, the tester will turn on the electronic switch controlling the load. During the test process, the data display will cycle between discharged capacity (Ah), current discharge current (A) and battery voltage (V). When the battery voltage reaches the set termination voltage, the tester cuts off the load control switch, the displayed data stays on capacity (Ah) and flashes rapidly together with the corresponding indicator light. At this time, the displayed capacity is the actual discharge capacity of the battery. Pressing "OK" once can stop the flashing and let the data display stably. Pressing the "OK" button again restores to the power-on state, allowing you to replace the battery and test the next one......
Error codes and meanings:
Err1: Battery voltage higher than 15 V
Err2: Battery voltage lower than set termination voltage
Err3: The battery cannot withstand the load discharge current or the internal resistance of the circuit is too large
Err4: Current too high (current exceeds 3.1 A)
Secondary calibration operation:
Simultaneously press and hold the three buttons to power on the tester, enter calibration mode, display the number of calibration records, then enter the formal calibration sampling program displaying 0u0 A. At this time, short-circuit the positive and negative input terminals and press the "OK" button once to complete displaying J10u. Apply a standard DC voltage of 10.00 V between the positive and negative input terminals and press the "OK" button once, then it displays J2.0 A. Apply a constant DC current of 2.0 A to the output negative terminal (inflow direction) and the input negative terminal (outflow direction), then press the "OK" button once to complete calibration. The tester will perform a preliminary review of the calibration data. If the calibration data is reliable, it will sequentially display 4 calibration values before exiting. If the preliminary review deems the data unreliable, it will discard the data and exit.



Ratings & reviews
No reviews yet. Purchased this product? Share your experience.
Checking review eligibility…
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Be the first to ask about this product.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.