Skip to content
Cart0 items in cart
Menu

Brand: AurumPCB

2String7.4V 8.4V 18650 Lithium battery protection board With balance 20A Current Balanced version

Sale price: $0.83Regular price: $0.91(-9%)

30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.

Product details

Description

HW-391 2S 7.4V/8.4V 20A Lithium Battery BMS with Balancing

The HW-391 is a balancing protection board for two-series lithium cells with 3.7V nominal and 4.2V full-charge ratings. The documented limits are 20A continuous discharge and 10A continuous charging, subject to cooling.

Features and use

  • The documented board uses a balancing resistor to discharge a cell that reaches its threshold early.
  • Initial battery connection may require charging before an output is present.
  • The specifications distinguish the continuous discharge limit from the continuous charging limit.

Product details

Product Name: 2 Series 8.4 V 20 A Lithium Battery Protection Board (Balanced Version)

Product Model: HW-391

Charging Voltage: DC 8.4~9 V

Continuous Discharge Current: Maximum 20 A (If the heat dissipation environment is poor, please reduce the load current for use)

Continuous Charging Current: Maximum 10 A

Product Size: 48 × 20 × 3.5 mm

Applicable Selection: Suitable for lithium batteries with a nominal voltage of 3.7 V and a full charge of 4.2 V

(Including 18650, 26650, polymer lithium battery), can carry starting current of 25 A, power drills below 50 W, or 168 W resistive loads

Precautions: To successfully start the drill, it requires 2 10C-20cd power batteries, or 4 5C-10c power batteries (Recommended power battery models: Sony vtc4, vtc4a, vtc5, vtc6). The connecting wires for OV and 8.4 V should use copper wire of more than 2 square millimeters (nickel strips cannot be used).

Precaution 2: When connecting the battery for the first time, it needs to be charged before there is an output. Strictly follow the diagram to connect OV, 4.2 V, and 8.4 V. When soldering wires, do not touch any components on the board, and do not intentionally short-circuit.

Precaution 3: When connecting the battery for the first time or during charging, as long as a single battery exceeds 4.2 V, the "430" resistor will generate heat and discharge (discharge stops generating heat at around 4.19 V). If the "430" resistor generates severe heat (too hot to touch), please check if the wiring is incorrect.

2S20 A Electrical Parameters
Item Minimum Value Typical Value Maximum Value Unit Remarks
Self-consumption Current 12 18 24 uA
Overcharge Protection Voltage 4.2 4.25 4.3 V
Balancing Start-up Voltage 4.17 4.2 4.23 V Balanced Version
Balancing Current 95 100 105 mA Balanced Version
Balancing Heat Dissipation Power 0.78 0.86 0.95 W Balanced Version
Overcharge Recovery Voltage 4.1 4.15 4.2 V
Over-discharge Protection Voltage 2.4 2.5 2.6 V
Recovery Voltage After Over-discharge Protection 2.8 3 3.2 V 1C Discharge
Recovery Voltage After Over-discharge Protection 3.2 3.5 3.8 V 2C Discharge
Over-discharge Recovery Voltage 2.5 2.6 2.7 V
Conduction Internal Resistance 5 6 7 mΩ
Overcurrent Protection Current 19 22 25 A
Overcurrent Delay Time 50 100 150 ms
Continuous Operating Current 0 20 20 A Resistive Load
Continuous Output Power 0 168 168 W Resistive Load
Ambient Temperature -40 25 85 °C

The image below is a module discharge diagram. The battery is 2-series connected, and the connected battery must meet a 20 A discharge current, which can be achieved by connecting batteries in parallel or purchasing batteries with high discharge currents. For example, if the battery is 2000 mAh with a 10C discharge rate, then only 2-series 2-parallel connections are needed to reach a maximum current of 40 A. Stable discharge requires 2-series 4-parallel connections, and attention must be paid to heat dissipation, as the battery capacity will drop rapidly during discharge.

HW-391 2S 7.4V/8.4V 20A Lithium Battery BMS with Balancing — wiring and connection diagram

The image below is a battery charging diagram, 2-cell battery, fully charged at 8.4 V, charging power supply voltage DC8.4~9 V, charging current depends on the current value set by the charging power supply and the battery charge level, maximum not exceeding 10 A.

HW-391 2S 7.4V/8.4V 20A Lithium Battery BMS with Balancing — wiring and connection diagram
Product details 2
Fault handling:
Fault phenomenon Fault inspection and cause Handling method and warranty
Unable to charge Measure the voltage of 3 groups of batteries; if one group's battery voltage is below approximately 4.25 V, the protection board will activate overcharge protection. Pair up the battery pack properly; do not mix good batteries with poor ones (normal function, no warranty needed).
Unable to discharge Measure the voltage of 4 groups of batteries; if one group's battery voltage is below approximately 2.5 V, the protection board will activate over-discharge protection. Pair up the battery pack properly; do not mix good batteries with poor ones (normal function, no warranty needed).
Charging/discharging failure Incorrect wiring for 0 V, 4.2 V, 8.4 V Rewire or replace with a new board (man-made fault, not covered by warranty).
Overcharge/over-discharge failure Incorrect wiring for 0 V, 4.2 V, 8.4 V Rewire or replace with a new board (man-made fault, not covered by warranty).
Discharge protection Check whether the battery pack has sufficient discharge capability; check whether the load's starting current exceeds the overcurrent working current of the protection board. Replace with a battery pack having stronger discharge capability, or a protection board with higher current rating (exceeds operating range, no warranty needed).
Component cold solder joint One pin of the component is not connected to the PCB pad. Re-solder (can be sent back for warranty service).
Component shorted solder joint There is a connection short between two or more pins of the component. Remove the component and re-solder it (can be sent back for warranty service).
Electrostatic breakdown A In an unpowered state, measure the G, D, and S terminals of the MOSFET; if both forward and reverse resistance between any two pins are 0 Ω, it indicates breakdown. Remove and replace the MOSFET (can be sent back for warranty service).
Electrostatic breakdown B Remove the MOSFET and measure the resistance between the G and D terminals, and between the G and S terminals; if there is measurable resistance, it indicates breakdown. Under normal conditions, the resistance should be infinite. Remove and replace the MOSFET (can be sent back for warranty service).

Shipping & support

  • Ships from China.

    We deliver to most countries worldwide. Shipping charges are shown at checkout.

  • Tracked delivery.

    Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.

  • Need express shipping?

    Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.

  • Technical help.

    Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.

  • If a product arrives defective:

    contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.

  • Bank transfer orders.

    Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.

Cart

0

Your cart is empty.

Looks like you haven't added anything to your cart yet.

Search