Image 2 of 4
Brand: AurumPCB
30-day returns on eligible items. Return shipping is generally paid by the customer. Read the return policy for conditions and exceptions.
This four-series protection board range includes balancing and chemistry-specific lithium-ion and LiFePO4 versions. Match the selected version to the pack's cell voltage and application; the description includes restrictions on high-inrush loads.
Lithium battery protection boards cannot be used for lithium iron phosphate batteries, xenon lamps, electric drill battery packs, electric fishing machine battery packs, electric bicycle battery packs, children's vehicle batteries, power motors above 550, and 1 W fisheye LED lights. Customers purchasing the above combinations please take note!
Within the described power range, it is suitable for the following products:
Massager battery packs, LED light backup power supplies, 12 V electronic products, solar street light battery packs, surveillance backup power supplies, and other products.
Lithium iron phosphate protection boards cannot be used for xenon lamps, battery packs for electric hand drills, battery packs for power tools, battery packs for electric fishing machines, vacuum cleaners, battery packs for robot vacuums, battery packs for electric bicycles, batteries for children's ride-on cars, high-power motors above 550, and 1 W LED fisheye lights. Customers purchasing the above combinations please take note!
Note: For products discharging at currents above 3 A, the battery discharge rate must be 3C or higher.
Rate calculation formula: For a 1C rate battery, a capacity of 2000 equals 2AH*1=2 A working current.
For a 3C rate battery, a capacity of 2000 equals 2AH*3=6 A working current.
If the battery heats up during use, it means the battery rate is not suitable. This situation cannot be used for a long time, and the battery will be damaged quickly.
Note 1: Strictly follow the diagram for wiring 0 V (B-), 3.7 V (B1), 7.4 V (B2), 11.1 V (B3), 14.8 V (B+). Do not intentionally short-circuit!
Note 2: After connecting the wires, it needs to be charged first before there is an output.
Note 3: When connecting 4 sets of batteries in series, please ensure that the voltage of each set is the same. If they are different, please charge each set individually to full capacity before using them in series. During discharge testing, the set of batteries with the fastest voltage drop is a poor battery.
Explanation: Do not mix good batteries with poor batteries! The closer the capacity/internal resistance of the 4 sets of batteries, the better! (The performance of 2 good batteries + 4 poor batteries = the performance of 4 poor batteries).
| Configuration | Basic Item | Specification | Unit | Remarks |
|---|---|---|---|---|
| Current | Continuous Discharge Current | 30 | A | Pay attention to temperature |
| Instantaneous Discharge Current | 56 | A | ||
| Charging | Charging Voltage | Lithium battery charger 16.8 V | V | Switching power supply 17-18 V |
| Charging Current | 20 (max) | A | ||
| Overcharge Protection | Overcharge Detection Voltage | 4.28 ± 0.05 | V | Single cell |
| Overcharge Protection Delay | 0.5 | S | ||
| Overcharge Release Voltage | 4.08±0.05 | V | Single cell | |
| Charge Balancing | Charge Balancing Detection Voltage | 4.2±0.05 | V | |
| Charge Balancing Release Voltage | 4.2±0.05 | V | ||
| Charge Balancing Current | 45 | mA | ||
| Over-discharge Protection | Over-discharge Detection Voltage | 2.5±0.08 | V | |
| Over-discharge Detection Delay | 0.1 | S | ||
| Over-discharge Release Voltage | 2.9±0.1 | V | ||
| Overcurrent Protection | Overcurrent Detection Voltage | 150 | mV | |
| Overcurrent Detection Delay | 40 | mS | ||
| Overcurrent Protection Current | 56±10 | A | ||
| Overcurrent Protection Release Condition | Disconnect load | |||
| Short-circuit Protection | Short-circuit Protection Condition | External load short circuit | Prohibit short circuit | |
| Short-circuit Detection Delay | 150 | uS | ||
| Short-circuit Protection Release Condition | Disconnect load | |||
| Temperature Protection | Temperature Protection | / | ℃ | Can add external temperature switch |
| Internal Resistance | Main Circuit On-resistance | ≤20 | MΩ | |
| Self-consumption | Operating Current | ≤30 | uA | |
| Sleep Current (when current is excessive) | ≤20 | uA | ||
| Operating Temperature | Temperature Range | Minus 20 to plus 80 | ℃ | |
| Board Size | 56 × 48 × 4 | MM |
Note: For better consistency balancing and a more effective equalization result, try to use an open-source charger with 17 V voltage and a current of 0.2 times the capacity (auto-stop current below 30 mA). Because the equalization current of the equalization IC is around 65 mA, and most 16.8 V lithium battery chargers on the market will auto-stop when the charging current detection is below 100 mA, no power is charged in before equalization is complete, causing the voltage of each battery group to be unbalanced. Regarding the issue of voltage drop between the battery voltage and the output terminal voltage, the working principle of this type of protection board is negative electrode protection. When just assembled, some may have a voltage drop of 0.1~0.3 V. After several cycles of charging and discharging, the voltage drop will decrease, which is normal. Try not to use a 16 V power supply for the charger. A fully charged 4-series lithium battery is 16.8 V; charging with a 16 V power supply will result in incomplete charging, and the protection board will not activate protection, so it will keep charging continuously. Long-term use will affect battery life. Thank you for your understanding.
| Configuration | Basic Item | Specification | Unit | Remarks |
|---|---|---|---|---|
| Current | Continuous Discharge Current | 30 | A | Pay attention to temperature |
| Instantaneous Discharge Current | 56 | A | ||
| Charging | Charging Voltage | LiFePO4 Charger 14.8 V | V | Switching Power Supply 15~16 V |
| Charging Current | 20 (max) | A | ||
| Overcharge Protection | Overcharge Detection Voltage | 3.75 ± 0.05 | V | Single Cell |
| Overcharge Protection Delay | 1300 | MS | ||
| Overcharge Release Voltage | 3.60±0.05 | V | Single Cell | |
| Cell Balancing | Cell Balancing Detection Voltage | 3.6±0.05 | V | |
| Cell Balancing Release Voltage | 3.59±0.05 | V | ||
| Cell Balancing Current | 58 | mA | ||
| Over-discharge Protection | Over-discharge Detection Voltage | 2.10±0.08 | V | |
| Over-discharge Detection Delay | 145 | S | ||
| Over-discharge Release Voltage | 2.30±0.1 | V | ||
| Overcurrent Protection | Overcurrent Detection Voltage | 200 | mV | |
| Overcurrent Detection Delay | 20 | mS | ||
| Overcurrent Protection Current | 56±10 | A | ||
| Overcurrent Protection Release Condition | Disconnect Load | |||
| Short-circuit Protection | Short-circuit Protection Condition | External load short circuit | Prohibit Short Circuit | |
| Short-circuit Detection Delay | 150 | uS | ||
| Short-circuit Protection Release Condition | Disconnect Load | |||
| Temperature Protection | Temperature Protection | / | ℃ | Can add external temperature switch |
| Internal Resistance | Main Circuit Conduction Internal Resistance | ≤20 | MΩ | |
| Self-consumption | Working Current | ≤30 | uA | |
| Sleep Current (During Over-discharge) | ≤20 | uA | ||
| Operating Temperature | Temperature Range | -20 to +80 | ℃ | |
| Board Size | 56 × 48 × 4 | MM |
Note: To achieve better balancing effects and consistency, try to use a switching power supply with a voltage of 15 V and a current of 0.2 times the capacity for charging (auto-stop current below 30 mA). This is because the current used by the balancing IC is around 65 mA, while most 14.8 V iron-lithium chargers on the market will automatically stop when the charging current detection falls below 100 mA, resulting in no charge entering before balancing occurs, causing an imbalance in the voltage of each battery group. Regarding the issue of voltage drop between the battery voltage and the output terminal voltage, the working principle of this type of protection board is negative electrode protection. When newly assembled, some may experience a voltage drop of 0.1-0.3 V. After several cycles of charging and discharging, the voltage drop will decrease, which is a normal phenomenon. Try not to use a 14 V power supply for the charger. A fully charged 4-series lithium iron phosphate battery is 14.4-14.8 V. Charging with a 14 V power supply will result in incomplete charging, and the protection board will not protect either, so it will keep charging continuously. Long-term use will affect the battery life. Thank you for your understanding.
Model: HX-4S-F30 A
Size: 56 × 48 × 4 mm
Upper limit current: Within 30 A
Charging current: Within 30 A
Balanced charging: Yes
Short circuit protection: Yes
Applicable assembly:
Nominal 3.7 V cell/4 series





Ratings & reviews
No reviews yet. Purchased this product? Share your experience.
Checking review eligibility…
Product FAQ
Have a question? Anyone can ask. No sign-in or email verification is required.
Be the first to ask about this product.
We deliver to most countries worldwide. Shipping charges are shown at checkout.
Our default carrier is 4PX, with typical delivery of 7–10 days to North America and Europe. Actual times vary by destination and customs clearance.
Email order@aurumpcb.com to ask about DHL or FedEx and the additional cost.
Contact support@aurumpcb.com for setup and troubleshooting. Our engineers usually reply within 24 hours on working days.
contact us for troubleshooting. Once a product defect is confirmed, you can choose a refund or replacement without returning the original.
Send your product list and quantities to order@aurumpcb.com for a quotation and payment instructions.